Iron Mountain Data Centres are located globally. Learn more about where and what each facility offers in our Locations Overview.

18 March 20206 mins
Iron Mountain Data Centers Location Overview

NEW JERSEY (NJE-1)

  • 3003 Woodbridge Ave, Edison, NJ 08837
  • Available Carriers: 20
  • Total Potential Capacity: 26.1 MW
  • Facility Size: 830,000 SF
  • N+1 chillers and CRAHs, 2N generators and UPSs

NORTHERN VIRGINIA (VA-2)

  • 11660 Hayden Road, Manassas, VA 20109
  • Available Carriers: 13
  • Total Potential Capacity: 24 MW
  • Facility Size: 221,578 SF
  • N+1 with block redundant power and chillers, N+1 and N+2 CRAHs, block redundant (N+1) generators and UPSs

OHIO (OHS-1)

  • 3366 S Tech Blvd, Miamisburg, OH 45342
  • Available Carriers: 7
  • Total Potential Capacity: 1.4 MW
  • Facility Size: 44,000 SF
  • N+1 chillers and CRAHs, 2N generators and UPSs

KANSAS CITY (KCM-1)

  • 6301 Winchester Ave, Suite 817, Kansas City, MO 64133
  • Available Carriers: 4
  • Total Potential Capacity: 3.9 MW
  • Facility Size: 49,503 SF
  • N+1 chillers, N generators, 2N or N+1 UPSs available

PHOENIX (AZP-2)

  • 4802 East Van Buren Street, Phoenix, AZ 85008
  • Available Carriers: 25+
  • Total Potential Capacity: 48 MW
  • Facility Size: 309,066 SF
  • N+1 with block redundant power and chillers, N+1 and N+2 CRAHs, block redundant (N+1) generators and UPSs

AMSTERDAM (AMS-1)

  • J.W. Lucasweg 35, 2031 BE Haarlem, Netherlands
  • Available Carriers: 48
  • Total Potential Capacity: 14.1 MW
  • Facility Size: 17,754 M2
  • N+1 chillers, 2N generators, 2N or N+1 UPSs

SINGAPORE (SIN-1)

  • 1 Serangoon North Ave 6, Singapore 554502
  • Available Carriers: 7
  • Total Potential Capacity: 6 MW
  • Facility Size: 153,000 SF
  • N+1 with block redundant power and chillers, room plus 4 (N+20%) CRAHs, N+1 CRAHs, block redundant (N+1) generators and UPSs

BOSTON (BOS-1)

  • 171 Bearfoot Rd, Northborough, MA 01532
  • Available Carriers: 3
  • Total Potential Capacity: 3.6 MW
  • Facility Size: 21,871 SF
  • N+1 chillers, 2N generators, 2N or N+1 UPSs

NORTHERN VIRGINIA (VA-1)

  • 11680 Hayden Road, Manassas, VA 20109
  • Available Carriers: 13
  • Total Potential Capacity: 12.4 MW
  • Facility Size: 167,958 SF
  • N+1 with block redundant power and chillers, N+1 and N+2 CRAHs, block redundant (N+1) generators and UPSs

WESTERN PENNSYLVANIA (WPA-1)

  • 1137 Branchton Rd, Boyers, PA 16020
  • Available Carriers: 7
  • Total Potential Capacity: 15.5 MW
  • Facility Size: 333,000 SF
  • Block redundant (N+1) generators, full 2N design UPSs in phase 1, block redundant in phase 2

DENVER (DEN-1)

  • 4300 Brighton Blvd, Denver, CO 80216
  • Available Carriers: 12
  • Total Potential Capacity: 14.4 MW
  • Facility Size: 179,666 SF
  • N+1 chillers, N+2 CRAHs, minimum of N+1 AHUs, N+1 generators, distributive redundant N+1 UPSs

PHOENIX (AZP-1)

  • 615 N 48th Street, Phoenix, AZ 85008
  • Available Carriers: 25+
  • Total Potential Capacity: 41 MW
  • Facility Size: 588,669 SF
  • N+1 with block redundant power and chillers, N+1 and N+2 CRAHs, 2N+1 generators, 2N and 2N+1 UPSs

SCOTTSDALE (AZS-1)

  • 8521 E Princess Dr, Scottsdale, AZ 85255
  • Available Carriers: 13
  • Total Potential Capacity: 5.7 MW
  • Facility Size: 121,000 SF
  • N+1 chillers, generators and CRAHs, 2N UPSs

LONDON (LON-1)

  • 724-729 Dundee Road, Slough, SL1 4JU, UK
  • Available Carriers: 11
  • Total Potential Capacity: 10 MW
  • Facility Size: 13,935 M2
  • N+1 chillers, block redundant (N+1) generators and UPSs

FRANKFURT (FRA-1)

  • Borsigallee 1, 60388 Frankfurt am Main Germany
  • Available Carriers: TBD
  • Total Potential Capacity: 27 MW
  • Facility Size: 36,040 M2
  • Chillers and CRAHs TBD upon construction completion, distributed redundant generators and UPSs